Post Offer Free
China Zhuhai Dshing Import&Export Co.,ltd
China Zhuhai Dshing Import&Export Co.,ltd  

Gold Index: 15432

You are here: home  > lab instruments  > DSH128 Gas Chromatograph DSH128 Gas Chromatograph

DSH128 Gas Chromatograph DSH128 Gas Chromatograph 

Place of Origin: Guangdong, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail


Visible Spectrophotometer

I.Technical characteristics:

1. Gas path control technology using ECD. Flow pressure within a set range, arbitrarily set, to automatically adjust a throttle function.

2. High precision program temperature control system , the oven temperature could be controlled at ± 0.02 ℃.

3. With complete system self-test function and automatic fault recognition.

4. Have a system of automatic parameter memory function, all parameters can be automatically controlled by workstation, ready to call the store analytical conditions.

5. TCD filament gas cut off  with automatic protection function

6. With twenty external event control functions.

7. The network data communication and remote control.

8. Valve configurations with a variety of solutions.

9. High reliability and high sensitivity detector. Column oven:

10. Temperature range: room temperature + 5 ℃ ~ 400 ℃

11. Control accuracy: ± 0.02 ℃

12. Temperature programming: 9 bands / 10 platform

13. Maximum heating rate: 60 ℃ / min

14. Single-channel compensation algorithm

15. Automatic cooling injector:

16. You can load three injector

17. Injector unit: split / splitless injector detector:

18. You can load three detectors, gas detectors using PPC control

19. Hydrogen flame ionisation detector: Temperature range: + 7 ℃ ~ 400 ℃ detection limit: ≤ 3 × 10-12g / s sample: C16

20. Micro thermal conductivity detector (μ-TCD): Temperature range: + 7 ℃ ~ 400 ℃ Sensitivity: ≥ 10000mV × .ml / mg sample: C16

21. Electron capture detector (ECD): Temperature range: 7 ℃ ~ 350 ℃ sources: 63Ni10 ~ 12mci minimum detectable amount: 8 × 10-14g/ml sample: г666

22. Flame photometric detector (FPD): Temperature range: + 7 ℃ ~ 350 ℃ detection limit: ≤ 3 × 10-12g / s (P) ≤ 3 × 10-11g / s (S) sample: formaldehyde parathion carrier gas flow rate:

23. Carrier gas flow control (EFC) and the head pressure control (EPC)

24. Pressure setting range: 0 ~ 100Kpa

25. Total flow setting range: 0 ~ 200ml/min (N2)

26. Auxiliary gas: 0 ~ 100ml/min (H2); 0 ~ 500ml/min (Air)


bigPhoto
 Ms. Angel

Tel: 86-756-8305811
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Related Products

Company Info

China Zhuhai Dshing Import&Export Co.,ltd [China (Mainland)]


Business Type:Trading Company
City: Zhuhai
Province/State: Guangdong
Country/Region: China (Mainland)

You May Like:

Product (300)